Home> Products> Temperature Controller> Intelligent Temperature Controller> XMT-JK808 Series MultiWay Intelligent Temperature Controller
XMT-JK808 Series MultiWay Intelligent Temperature Controller
XMT-JK808 Series MultiWay Intelligent Temperature Controller
XMT-JK808 Series MultiWay Intelligent Temperature Controller

XMT-JK808 Series MultiWay Intelligent Temperature Controller

Get Latest Price
Payment Type:T/T,Paypal
Incoterm:FOB,CFR,CIF,EXW
Min. Order:2 Piece/Pieces
Transportation:Ocean,Land,Air,Express
Port:NINGBO,SHANGHAI
Product Attributes

Model No.XMT-JK808

BrandCJ

Control TypelDigita

Control MethodElectronic Type

Packaging & Delivery
Selling Units : Piece/Pieces
Product Description

XMT-JK808 series intellective temperature adjustment instrument

XMT-JK808 series intelligent (Temperature controller)temperature control instrument is a new meter to meet the market needs. The meter is controlled by single chip microcomputer, every channel setting value and some parameters can be set up independently. It has the advantages of small volume, low power consumption, simple operation, easy control, stable operation, reliable, economical characteristics. It is widely used in the temperature automatic control systems of machinery、chemical、ceramics、light industrial、metallurgy、petrifaction and heat treatment, and so on.

Ⅰ、Main technical specification  

1、Input(can be selected):CU50(-50~150)、PT100(-80~600)、K(-30~999)、

E(-30~700)、J(-30~900)、T(199~400)

2、Measurement deviation: ≤±0.5%F·S±1B   Cold end compensating deviation: ≤±2.0℃

3、Sampling cycle: 0.5S

4、Control cycle: relay output 2~120S , other is 2S.

5、Relay output contact capacity: AC220V/5A (resistance load) or AC220V/0.3A (perceptual load)

6、Alarm relay contact output:AC220V/1A(resistance load)

7、Driving solid relay signal output: driving electric current≥15mA, voltage≥9V.

8、Power supply: AC85V~242V, 50/60Hz

9、Working condition: temperature 0~50.0℃, relative humidity≤85%RH, without corrode and strong electric radiation.

Ⅱ、Panel instruction(consult)

1

ALM1~ALM8:The first channel to the eighth channel alarm output indicator light ( red);

OUT1~OUT8:The first channel to the eighth channel control output indicator light ( green );

CH1~CH8 key:The first channel to the eighth channel corresponding channel parameter setting key;

SET/Ⅰkey:The first channel to the fourth channel function setting key;    

SET/Ⅱkey:The fifth channel to the eighth channel function setting key;

◄ key(left):The first channel to the fourth channel shift key;  

◄ key(right):The fifth channel to the eighth channel shift key;

▼ key(left):The first channel to the fourth channel data decrease key;   

▼ key(right):The fifth channel to the eighth channel data decrease key;

▲ key(left):The first channel to the fourth channel data increase key;   

▲ key(right):The fifth channel to the eighth channel data increase key;

三、Model significance

XMT -  JK 8      8       

  (1)     (2)  (3)  (4)  (5)   (6)

⑴Meter faceplate and Installation dimension(mm):160×80×130;  152×76;

⑵Design serial number:Eight channel independent control meter, PID and ON/OFF control can optional;

⑶ Alarm:‘0’:no set alarm; ‘1’:one alarm ( alarm mode optional);  

⑷Input signal: “8”: Free exchange of the input signal

⑸ Main control mode: ‘space’: relay normally-open normally-closed contact output; ‘A’:Single phase zero trigger control;     ‘G’:Solid state relay control output

(6) Suffix:‘K’:with 485 or RS232 Communication module interface;  ‘WT’:With an external printer module interface     

四、Internal parameters:

1 2

 Ⅴ、Instrument operation

5.1The first menu setting ( public menu setting ):

Press the function key ( SET / I key) 3 seconds, enter into the first channel to the fourth channel the  first menu setting state, this time ’ the first channel display window ‘ and ‘ the second channel display window ‘ respectively display the first menu parameter symbols and parameter values, this time you can press respectively correspond to the ◄shift)、▲、▼ keys to change the parameter value, after the completion modified, press SET / I key to preserve and enter into the next parameter; modify the other parameters by the same method. If in the setting without any operation 10 seconds, the meter will automatically save and exit the modified state.

 Press the function key ( SET / II key) 3 seconds, enter into the fifth channel and the eighth channel the first menu setting state, this time ’ the fifth channel display window ‘ and ‘ the sixth channel display window ‘ respectively display the first menu parameter symbols and parameter values, modification method is as above.

5.2The second menu setting ( each channel corresponding to the menu setting ):

 The first channel to the fourth channel parameters respectively press CH1~CH4 three seconds to enter into the corresponding channel menu item, this time ’the first channel display window ‘ and ‘the second channel display window ‘ respectively display the corresponding channel the second menu parameter symbols and parameter values, this time you can press respectively correspond to the ◄shift)、▲、▼ keys to change the parameter value, modification method is as above “5.1The first menu setting”.

The fifth channel to the eighth parameters respectively press CH5~CH8 three seconds to enter into the corresponding channel menu item, this time ’the fifth channel display window’ and ‘the sixth channel display window’ respectively display the corresponding channel the second menu parameter symbols and parameter values, this time you can press respectively correspond to the ◄shift)、▲、▼ keys to change the parameter value, modification method is as above “5.1The first menu setting”.

Ⅵ、Setting itself

The meter use in the first time or the surroundings have changer, finding it control not good,  this time you need use the setting itself. For example:

At first set up the corresponding channel setting value, and then enter into the corresponding channel menu, set the corresponding Hy is 0.51℃, set the AT=1, “AT” and the measured temperature value flash alternately, the meter enter into setting itself, the meter have three times vibrate, automatic preserved P, I, D parameter and the setting itself finish.

Note①when the power off during setting itself, as the meter has the memory, it will restart setting itself next time.

②when it need artificially exit during setting itself, set the corresponding channel self-tuning

the parameter AT to 0 so that can exitbut the setting result will not be valid.

Connection scheme(consult)

2

Note:1)The above diagram is an example of XMT-JK818, only for reference, controller’s specific connection should be confirm to the case’s connection.

2)The meter’s signal input used to isolate type Sensor, or that may affect the meter’s measurement.

Ⅷ、Fault Analysis and Clearance:

XMT-JK808 series adopt advanced production process, and have the strict test before leaving factory, it improve the reliability of the meter .The usual fault caused by the wrong operation or parameter setting. If you find the fault couldn’t be cope with, please record it, and contact with the agent or us. Sheet 8-1 is the usual fault of XMT-JK808 series in the daily application:

Sheet 8-1 Common fault handling

3

Attached 1:Statement of meter’s parameter attention letter and English letter

2

Note: Our company will continue to improve product technology, design specification. If change, please subject to the material object, without notice.



  • Previous: XMT-JK408 Series Multi Way Intelligent Temperature Controller
  • Next: XMZ-J8 Multi Way Intelligent Temperature Itinerant Detecting Controller

  • Home> Products> Temperature Controller> Intelligent Temperature Controller> XMT-JK808 Series MultiWay Intelligent Temperature Controller

    Contact

    • Tel: 86-574-58221595
    • Whatsapp: +8618957481197
    • Email: vera@yycj.com
    • Address: No. 9, Changqing Road, Yuyao, Ningbo, Zhejiang, China, Ningbo, Zhejiang China

    Send Inquiry

    Send Inquiry
    *
    *

    We will contact you immediately

    Fill in more information so that we can get in touch with you faster

    Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

    Send