XMT*608 series Intelligent Temperature Controller

Operation Instruction

Ⅰ、Survey

Thanks for your selection of our XMT*608 series intelligent Temperature controller.

XMT*608 series intelligent Temperature Controller,is double row 3-LED display, respectively display  temperature measurement value (PV) and temperature set value (SV) under normal mode;When it is time temperature control, respectively display temperature measurement value (PV) and running time count down (SV),and also provide kinds of time control method selection;The controller can input kinds of signal which are used interchangeably,it adopt ON/OFF(P=0时)、PID control,allowing an easy parameter setting and convenient inputting,is widely used over temperature automatic control systems of machinery、chemical、ceramics、light industrial、metallurgy、petrifaction and heat treatment and so on.

Ⅱ、Main technical Indexes

1、 Measurement deviation:±0.5F·S±1,additional cold end compensating deviation±1℃

2、 Input(can be selected):CU50(-50~150)、PT100(-80~600)、K(-30~999)、E(-30~700)、

J(-30~900)、T(199~400)

3、 Relay output (passive) contact capacity: AC250V 5A(resistance load)  period 2~120s can be adjusted.

4、 Time range:0~999s or 0~999m(can be selected)

5、 Driving solid relay signal output:Driving electric current >15mA  no-load voltage>12V,period is about 2S.

6、 Work power:110V~242V,50HZ    Power consumption<3W

7、 Work environment:0~50℃,relative humidity≤85%,without corrode and strong electric radiation.

Ⅲ、Controller panel

1、Controller panel(for reference)2、Connection(for reference)

1

★Controllers specific connection should be confirm to the cases connection

Ⅳ、Meaning of the model code

 XMT □—6    □8      □

 1  2     3     4       5     

1: the surface dimension

Blank:  160×80×85    Installation hole 156×76      

A:  96×96×80      Installation hole 92×92

D:  72×72×80     Installation hole 68×68        

E:  48×96×75     Installation hole 44×92

F:  96×48×75     Installation hole 92×44         

G:  48×48×110    Installation hole 44×44

S:  80×160×85    Installation hole 76×156        

B:60×120×90    Installation hole 56×116

L:Standard DIN35mm guide way installation             

C:80×120×35   wall set installation

2: Operation display method:‘6’ 3-key gentle push-switch setting,double row 3-LED digital display,PID control.

3:Additional alarm:

‘0’  no alarm;   

 ‘1’  upper limit alarm(upper deviation alarm when it is time temperature control) 

4:Input: ‘8’ input signal can interchange free(no voltage and current input)

5:Suffix   Blank:relay output G:solid relay output  T:Time control function

Ⅴ、Inner parameter Sheet 5-1

1 2 3 4

po


Flow chart:

2

Ⅵ、Operation

1、 Make the controller link with power supply, Sensor and control loop , and make the power on, the controller will start setting itself for 1S.

2、 After completing setting itself ,the controller will enter into normal measuring state,the upper row PV window display measuring value ,the lower row SV window display set value.

3、 The first menu

A、Time set value modification

Common temperature control mode: Press▲or▼for 3s to modify set value ,the upper row PV window display measurement value ,the lower row SV window display set value , press▲ or▼ to modify,long time to press can accelerate plus or minus. After modification,press SET to save and exit. If don’t press any key, it will save and exit automatically after 10s.

Time control mode:Press▲for 3s to enter into temperature set value modification state ,the upper row PV window display parameter attention “”,the lower row SV window display parameter value,press▲ or ▼to modify,long time to press can accelerate plus or minus. After modification,press SET to save and exit. If don’t press any key, it will save and exit automatically after 10s.

★B、Time set value modification(when it is time &temperature control)

Press▼for 3s to enter into time set value modification state,the upper row PV window display parameter attention “”,the lower row SV window display parameter value, press▲ or ▼to modify,long time to press can accelerate plus or minus. After modification,press SET to save and exit. If don’t press any key, it will save and exit automatically after 10s.

Inner parameter setting(detailed refer to Sheet5-1)

(1) The second menu

Press SET for 3s to enter into the second menu,the upper row window display parameter code, the lower row window display parameter value,press▲ or▼to modify,long time to press can accelerate plus or minus. After modification,press SET to save and exit. If don’t press any key, it will save and exit automatically after 10s.

(2) The third menu

Press SET +▲to enter into the third menu,setting method is the same as above.

4、 Setting itself

First set the fixed value, and then enter the menu ,set  to ,At light is on,the controller enter into setting itself state, set return difference about 0.5~1,here the controller is ON/OFF control,after three times oscillation,new parameter 、、 can be confirmed and saved,AT light goes out,the controller be reset and enter into the control state.  

★6、Time control function(when it is time& temperature control):

Cut time control side at any time,time will get back to the initial state;When getting time control side, the controller will run according to setting time count down.

o

Fault Analysis and Clearance

XMT*608 adopt advanced production process, and have the strict test before leaving factory, it improve the reliability of the meter .The usual fault caused by the wrong operation or parameter setting .If you find the fault couldn’t be cope with, please record it, and contact with the agent or us. Sheet 7-1 is the usual fault of XMT*608 in the daily application:

Sheet7-1 Common fault disposal

zh

★Remark:Our company will improve product technology, design and specification, it is confirm to the object.

Attached 1:Statement of meter’s parameter attention letter and English letter

2

  • Previous: XMT-308 Series Universal Input Type Intelligent Temperature Controller
  • Next: XMT-808 Series Universal Input Type Intelligent Temperature Controller

  • Home> Products> Temperature Controller> Intelligent Temperature Controller> XMT-608 Series Universal Intelligent Temperature Controller

    Contact

    • Tel: 86-574-58221595
    • Whatsapp: +8618957481197
    • Email: vera@yycj.com
    • Address: No. 9, Changqing Road, Yuyao, Ningbo, Zhejiang, China, Ningbo, Zhejiang China

    Send Inquiry

    Send Inquiry
    *
    *

    We will contact you immediately

    Fill in more information so that we can get in touch with you faster

    Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

    Send