EU-08 series Digital Display Temperature Controller
Temperature controller, Sensor
Ⅰ.Main Technical Indexes
1. Measurement deviation:Class±0.5%F·S±1B,additional cold end compensation
deviation ±1℃
2. Input Type:CU50(-50~150.0).PT100(-199.9~600.0).K(-30~1300).
E(-30~700).J(-30~900).T(199~400).S(-30~1600).
R(-30~1700).0~10V (-1999~9999) .4~20mA (-1999~9999).
3. Relay output contact capacity:AC220V , 5A(resistance load)
4. Linearity output:4~20mA(Client can adjust by himself)
5. Power output: 24VDC
6. 0.8"LED tube and four digit display
7. Size and Installation hole(mm):96×48×110 92×44
8. Working power:AC 85V~242V,50/60HZ
9. Working condition:0~50℃,relative humidity≤85%,without corrode and strong electric radiation.
Ⅱ.Instrument panel and connection scheme
1.Instrument panel(consult) 2.Instrument connection(consult)
Notice: linearity voltage0~10V can be input directly by 1.4 terminal,and the input of linearity current 4~20 mA can connect 4.5 terminal use lead then input signal from 1.4 terminal.
Ⅲ.Interior parameter
Sheet 3-1
Series | Attention | Name | Setting range | Remark | Ex-Factory | |
First
menu |
1 |
|
Upper limit alarm |
Determined by DIL.DIH | measured value ≥AL1, the meter have upper limit alarm. measured value <AL1-Hy, the meter will free from the upper limit alarm. |
2000 |
2 |
|
Lower limit alarm | measured value ≤ AL2, the meter have lower limit alarm. measured value>AL2+Hy, the meter will free from the lower limit alarm. |
1000 | ||
3 |
| Control by drop in level |
0.1~50.0 | The return difference of two alarm outputs can prevent the frequent fluctuations in alarm output. |
5 | |
4 |
| Measuring error | -20.0~20.0 | Thermocouple and thermal resistance can modify the scope of ±20.0; Current and voltage signals can modify the scope of ±200(dp=0) |
0 | |
| 5 |
| Electronics lock | 0~255 | =0 all the parameter can be revised or it can`t | 0 |
| ||||||
Second
Menu |
6 |
| Electronics lock |
0~255 | =0 all the parameter can be revised or it can`t | 0 |
7 |
|
Input type |
- | CU50().PT100().K().E().J().T().S(). R (). 0~10V(). 4~20mA() |
| |
8 |
|
Decimal point |
0~3 | When dp=0,display format is 0000; When dp=1,display format is 000.0; When dp=2,display format is 00.00; When dp=3,display format is 0.000 |
0 | |
9 |
|
Set upper limit |
≤ | Can set the lower/upper limit displaying input signal. When input signal is current or voltage , you can set the corresponding display number. As for other use, please refer to [Some useful samples for calibration"in the part No. Ⅳ |
LET'S GET IN TOUCH
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.