          XMTK- 3000 Series Digital Display Temperature Controller

XMTK-3000 Series Temperature controller can replace the traditional pull yards -type or potentiometer type digital display meter, which uses the touch buttons can freely set, single-row LED display, with a fixed PID control or NO/OFF return difference control can elect, and return difference is adjustable, also have Sensor error correction function. The instrument have a reliable control performance, cost-effective and wide application and so on.

Ⅰ、Technical Indexs:

1Input type and measuring range:

 K01300  E0800 S4001600  J01000

B8001800Pt100-50.0200.0; -200600   Cu50-50.0150.0

Note: The instrument input type and measuring range subject to the meter label.

2Display accuracy±1%F·S±1B    Additional cold junction compensation error≤2

3Control modeON/OFF controlreturn difference is adjustableor PID control

4Setting range of return difference 120

5Control proportion bandP):±9 or ±0.9 when temperature display has decimal point.

6PID control period30 seconds

7Sensor error translation scope amendment-2020

8Output modeRelay contact capacity AC220V/5A

         Drivng solid relay signaldriving electric current ≥ 15mAvoltage ≥ 9V

9PowerAC85242V  50Hz/60Hz   

Power consumption: less than 3W or other according to customer requirement

10Work environmenttemperature 050.0, relative humidity ≤ 85%RH, without corrode and strong electric radiation.

Ⅱ、Instrument panel(consult):

1)、Display window: Under the normal state, it displays the measured       

temperature value.

2)、Output indicator (OUT): When the meter has output ,the light is bright;      

when output is close, the indicator is out at the same time.

3)、Data increasing key):Under the normal display state, pressing the

key can increase the temperature set valueusing in combination with

the ▼ key to enter the parameters modification state.

4)、Data decreasing key):Under the normal display state, pressing the    

key can reduce the temperature set valueusing in combination with the  

▼ key to enter the parameters modification state. 

Parameter setting

3.1Set value of temperatureUnder the normal display state, directly press the data increasing keyor data decreasing keyto display the temperature set value, this time press (▲) or (▼) key to change the temperature set value, long pressing enables the data fast plus or minus. Without any operating conditions, the set value flashes 8 times and returnto normal display status.

3.2Parameter modificationUnder the normal display state, at the same time pressingandcan display the sensor error correction symbol "SC", in three seconds pressing (▲) or (▼) key will display and can modify the parameter value; if then again pressingandcan display the control return difference symbol “HY in three seconds pressing (▲) or (▼) key will display and can modify the parameter value; again press the (▲) and (▼) key to exit and return to the the normal display status. 

When display parameter symbol, in 3 seconds without any operation, the meter will return to the normal display; in the display parameters cases, if the set value flashes 8 times without any operation,the meter also will return to normal display.

3.3Contro modeDisconnect the meter control selection terminals,the meter is two place control; Connect the meter control selection terminals,the meter will automatically switch to PID control.

Control Output

When the meter is ON/OFF control

When the measured temperature value  (set valuereturn difference ),the relay total and low pass, total and high cut, while OUT indicator is light, the heater work;

When the measured temperature value >(set valuereturn difference ),the relay total and low cut, total and high pass, while OUT indicator is out, the heater stop working;

When the meter is PID controlThe meter implement control output according to the fixed PID value and control cycle.

Model Sense

XMT □ - 3 □ □ □ -Suffix

    2  3  4

Blank 1External size and Installation hole(mm)       Empty80×160×80  76×152     

‘S’160×80×80   152×76   ‘A’96×96×80    92×92    ‘B’60×120×105  56×114  

‘E’48×96×80   44×92     ‘F’96×48×80    92×44    ‘D’72×72×100   68×68     

 ‘G’48×48×90   44×44‘K’24×48×90    23×45      

Blank 2Control output mode

‘0’ two place controlrelay output  ‘4’ fixed PID controlrelay output

‘5’ Drivng solid relay signaloutput   7’ Drivng SCR zero passed pulse signal output

Blank 3Alarm mode ‘0’no alarm;    1one upper limit alarm;

Blank 4Input mode

Share to:

LET'S GET IN TOUCH

Contact

  • Tel: 86-574-58221595
  • Whatsapp: +8618957481197
  • Email: vera@yycj.com
  • Address: No. 9, Changqing Road, Yuyao, Ningbo, Zhejiang, China, Ningbo, Zhejiang China

Send Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send