EU-08 series Digital display temperature controller

EU-08 series Digital Display Temperature Controller

Temperature controller, Sensor

.Main Technical Indexes

1. Measurement deviation:Class±0.5%F·S±1B,additional cold end compensation

deviation ±1℃

2. Input Type:CU50(-50~150.0).PT100(-199.9~600.0).K(-30~1300).

E(-30~700).J(-30~900).T(199~400).S(-30~1600).

R(-30~1700).0~10V (-1999~9999) .4~20mA (-1999~9999).

3. Relay output contact capacity:AC220V , 5A(resistance load)

4. Linearity output:4~20mA(Client can adjust by himself)

5. Power output: 24VDC

6. 0.8"LED tube and four digit display

7. Size and Installation hole(mm):96×48×110 92×44

8. Working power:AC 85V~242V,50/60HZ

9. Working condition:0~50℃,relative humidity≤85%,without corrode and strong electric radiation.

.Instrument panel and connection scheme

1.Instrument panel(consult) 2.Instrument connection(consult)

Notice: linearity voltage0~10V can be input directly by 1.4 terminal,and the input of linearity current 4~20 mA can connect 4.5 terminal use lead then input signal from 1.4 terminal.

.Interior parameter

Sheet 3-1

Series

Attention

Name

Setting range

Remark

Ex-Factory

First

menu

1

Upper limit alarm

Determined by DIL.DIH

measured value ≥AL1, the meter have upper limit alarm.

measured value AL1-Hy, the meter will free from the upper limit alarm.

2000

2

Lower limit alarm

measured value ≤ AL2, the meter have lower limit alarm.

measured valueAL2+Hy, the meter will free from the lower limit alarm.

1000

3

Control by drop in level

0.1~50.0

The return difference of two alarm outputs can prevent the frequent fluctuations in alarm output.

5

4

Measuring

error

-20.0~20.0

Thermocouple and thermal resistance

can modify the scope of ±20.0;

Current and voltage signals can modify

the scope of ±200(dp=0)

0

5

Electronics

lock

0~255

=0 all the parameter can be revised or it can`t

0

Second

Menu

6

Electronics

lock

0~255

=0 all the parameter can be revised or it can`t

0

7

Input

type

-

CU50().PT100().K().E().J().T().S().

R (). 0~10V().

4~20mA()

8

Decimal point

0~3

When dp=0,display format is 0000;

When dp=1,display format is 000.0;

When dp=2,display format is 00.00;

When dp=3,display format is 0.000

0

9

Set upper limit

Can set the lower/upper limit

displaying input signal.

When input signal is current or voltage ,

you can set the corresponding display

number.

As for other use, please refer to [Some

useful samples for calibration"in the

part No.

Share to:

LET'S GET IN TOUCH

Contact

  • Tel: 86-574-58221595
  • Whatsapp: +8618957481197
  • Email: vera@yycj.com
  • Address: No. 9, Changqing Road, Yuyao, Ningbo, Zhejiang, China, Ningbo, Zhejiang China

Send Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send