Wholesale Discount High Quality Hygrometer - D Series Digital Voltmeter – Gongyi

Short Description:

Ⅰ、Survey:D series intellective electric meter(Digital Ammeter、Digital Voltmeter、Frequency Meter、Tachometer and so on)is a type of multifunctional composite type meter, it apply to electric power and electric network, field monitoring and display of automatic control systems and remote con...


Product Detail

Product Tags

Related Video

Feedback (2)

Our well-equipped facilities and excellent quality control throughout all stages of production enables us to guarantee total customer satisfaction for Temperature And Humidity Controller , Automatic Temperature Humidity Controller , Industrial Temperature Controller , We attend seriously to produce and behave with integrity, and because of the favor of clients in your house and abroad in the xxx industry.
Wholesale Discount High Quality Hygrometer - D Series Digital Voltmeter – Gongyi Detail:

Ⅰ、Survey:

D series intellective electric meter(Digital Ammeter、Digital Voltmeter、Frequency Meter、Tachometer and so on)is a type of multifunctional composite type meter, it apply to electric power and electric network, field monitoring and display of automatic control systems and remote control and measurement of automatic dispatch telemechanical device,its function is to output  standard current or voltage transfer signal using CPU operation electric network’s parameter, such as current、voltage、3 phase power、frequency and so on,and then A/D’s conversion. Also this meter has RS232 or RS485 communication interface be joined with long range data terminal TRU.

Ⅱ、Main technical specification

1、Accuracy Class: 0.5%F·S±1B

2、Display Digit:4

3、Reference Input:AC /AV:0~5A/0~500V   volts D.C.:0~199.9V   0~1000V

4、Power consumption:≤3W

5、Working power:AC85~242V,50/60HZ

6、Working circumstance:0~50℃,relative humidity≤85%,without corrode and electric radiation

Ⅲ、Panel board and connection

1、Panel board  

1

The panel board function of each model can follow the above drawing .

2、connection

2

Ⅳ、Operation

1、Interior parameter(only Current、Voltage model meter have this parameter)

Series

Attention

Name

Setting range

Manual

Remarks

0 LocK

Electronic lock

0255

Lock=18all the parameter can be Revised.  

18

1

 

dP

Display precision

03

dp0the decimal doesn’t display

dp1the decimal in tens

dp2the decimal in hundreds

dp3the decimal in thousands

0

2

dIH

Set upper limit Setting range determined by dpis in turn 9.999

99.99999.99999

2、Operational flowchart

3

3、connect according to the connection, the instrument will test by itself for 1S.

4、Interior parameter setting(parameter definition refer to parameter sheet)

Press SET key for 3S to enter the Interior parameter setting state,it display parameter code first,and then display parameter value after 2s,press▲、▼ to modify parameter value,and press SET to save and enter the next parameter setting ,exit till the setting finished. If not press any key ,it will save and exit automatically. 

5、★current、voltage mode:if the meter display has warp,you can press ‘SET’&▲&▼key at one time to clear.(please be cautious to use this function).

Ⅴ、Meaning of the model code

D □  □-□□   □- □

①   ②    ③    ④     ⑤     ⑥     

①:Series number L:Current model  Y:Voltage model   F-frequency   R-revolving speed

②:External dimension and Installation hole(mm):

T:160×80×85  156×76       A:96×96×90    92×92      D:72×72×90    68×68     

E:48×96×75    44×92       F:96×48×75    92×44       G:48×48×105   44×44

③:3-key soft push-switch setting, single row digital display,

④: Control output:  0: No alarm   1: A alarm   3: Two alarms  4: PID bit control  

5: PID solid-state control  6: PID SCR phase shifter control  7: PID SCR zero-crossing control
8: SCR three-phase zero-crossing control  9:4 ~ 20mA control output
⑤: The input nominal value:
No: AC current 5A input, the AC current for 0-9999 arbitrary setting, apply to all transformer       ammeter;   AC voltage for 0-500.0VAC;   

10: 0 ~ 10A  400: 0 ~ 400V  0.2: 0 ~ 200mA
⑥: Suffix: K-  RS485 communication function

Ⅵ、Fault Analysis and Clearance

Sheet 6-1 Common fault handling

fault symptom analysis of causes Disposal  measurement
The power on is unusual 1poor contact of power cord  

2power switch without lose

Check the power
Signal display do not correlate with the facts.(displayHHor0’) 1、Input nominal value overtop or under the meter’s display range Check the input value

Product detail pictures:

Wholesale Discount High Quality Hygrometer -
 D Series  Digital Voltmeter – Gongyi detail pictures

Wholesale Discount High Quality Hygrometer -
 D Series  Digital Voltmeter – Gongyi detail pictures

Wholesale Discount High Quality Hygrometer -
 D Series  Digital Voltmeter – Gongyi detail pictures

Wholesale Discount High Quality Hygrometer -
 D Series  Digital Voltmeter – Gongyi detail pictures


Related Product Guide:
Cooperation

"Quality very first, Honesty as base, Sincere assistance and mutual profit" is our idea, in an effort to create consistently and pursue the excellence for Wholesale Discount High Quality Hygrometer - D Series Digital Voltmeter – Gongyi, The product will supply to all over the world, such as: United Arab emirates , Anguilla , belarus , We have been very responsible for all details on our customers order no matter on warranty quality, satisfied prices, quick delivery, on time communication, satisfied packing, easy payment terms, best shipment terms, after sales service etc. We provide one-stop service and best reliability to our every customers. We work hard with our customers, colleagues, workers to make a better future.
  • The product classification is very detailed that can be very accurate to meet our demand, a professional wholesaler.
    5 Stars By Ella from Jamaica - 2017.03.07 13:42
    The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!
    5 Stars By Daphne from Rwanda - 2018.10.09 19:07

    Related Products