Short Description:

Ⅰ、Survey:D series intellective electric meter(Digital Ammeter、Digital Voltmeter、Frequency Meter、Tachometer and so on)is a type of multifunctional composite type meter, it apply to electric power and electric network, field monitoring and display of automatic control systems and remote con...


Product Detail

Product Tags

Related Video

Feedback (2)

Our well-equipped facilities and excellent excellent management throughout all stages of creation enables us to guarantee total buyer satisfaction for Humidity Adjuster , Temperature Sensor Instrument , Humidity Temperature , We cordially welcome customers from at home and abroad to join us and cooperate with us to enjoy a better future.
Renewable Design for 12v Time Relay - Digital Frequency Meter – Gongyi Detail:

Ⅰ、Survey:

D series intellective electric meter(Digital Ammeter、Digital Voltmeter、Frequency Meter、Tachometer and so on)is a type of multifunctional composite type meter, it apply to electric power and electric network, field monitoring and display of automatic control systems and remote control and measurement of automatic dispatch telemechanical device,its function is to output  standard current or voltage transfer signal using CPU operation electric network’s parameter, such as current、voltage、3 phase power、frequency and so on,and then A/D’s conversion. Also this meter has RS232 or RS485 communication interface be joined with long range data terminal TRU.

Ⅱ、Main technical specification

1、Accuracy Class: 0.5%F·S±1B

2、Display Digit:4

3、Reference Input:AC /AV:0~5A/0~500V   volts D.C.:0~199.9V   0~1000V

4、Power consumption:≤3W

5、Working power:AC85~242V,50/60HZ

6、Working circumstance:0~50℃,relative humidity≤85%,without corrode and electric radiation

Ⅲ、Panel board and connection

1、Panel board                   

1

The panel board function of each model can follow the above drawing .

2、connection

2

Ⅳ、Operation

1、Interior parameter(only Current、Voltage model meter have this parameter)

Series

Attention

Name

Setting range

Manual

Remarks

0 LocK

Electronic lock

0255

Lock=18all the parameter can be Revised.  

18

1

dP

Display precision

03 dp0the decimal doesn’t displaydp1the decimal in tens

dp2the decimal in hundreds

dp3the decimal in thousands

0

2

dIH

Set upper limit Setting range determined by dpis in turn 9.99999.99999.99999

2、Operational flowchart

3

3、connect according to the connection, the instrument will test by itself for 1S.

4、Interior parameter setting(parameter definition refer to parameter sheet)

Press SET key for 3S to enter the Interior parameter setting state,it display parameter code first,and then display parameter value after 2s,press▲、▼ to modify parameter value,and press SET to save and enter the next parameter setting ,exit till the setting finished. If not press any key ,it will save and exit automatically. 

5、★current、voltage mode:if the meter display has warp,you can press ‘SET’&▲&▼key at one time to clear.(please be cautious to use this function).

Ⅴ、Meaning of the model code

D □  □-□□   □- □

①   ②    ③    ④     ⑤     ⑥     

①:Series number L:Current model  Y:Voltage model   F-frequency   R-revolving speed

②:External dimension and Installation hole(mm):

T:160×80×85  156×76       A:96×96×90    92×92      D:72×72×90    68×68     

E:48×96×75    44×92       F:96×48×75    92×44       G:48×48×105   44×44

③:3-key soft push-switch setting, single row digital display,

④: Control output:  0: No alarm   1: A alarm   3: Two alarms  4: PID bit control  

5: PID solid-state control  6: PID SCR phase shifter control  7: PID SCR zero-crossing control
8: SCR three-phase zero-crossing control  9:4 ~ 20mA control output
⑤: The input nominal value:
No: AC current 5A input, the AC current for 0-9999 arbitrary setting, apply to all transformer       ammeter;   AC voltage for 0-500.0VAC;   

10: 0 ~ 10A  400: 0 ~ 400V  0.2: 0 ~ 200mA
⑥: Suffix: K-  RS485 communication function

Ⅵ、Fault Analysis and Clearance

Sheet 6-1 Common fault handling

fault symptom analysis of causes Disposal  measurement
The power on is unusual 1poor contact of power cord  2power switch without lose Check the power
Signal display do not correlate with the facts.(displayHHor0’) 1、Input nominal value overtop or under the meter’s display range Check the input value

Product detail pictures:

Renewable Design for 12v Time Relay -
 Digital Frequency Meter – Gongyi detail pictures

Renewable Design for 12v Time Relay -
 Digital Frequency Meter – Gongyi detail pictures

Renewable Design for 12v Time Relay -
 Digital Frequency Meter – Gongyi detail pictures


Related Product Guide:
Cooperation

We insist on offering high-quality creation with superior business enterprise concept, honest revenue plus the greatest and fast service. it will bring you not only the high quality solution and huge profit, but essentially the most significant is usually to occupy the endless market for Renewable Design for 12v Time Relay - Digital Frequency Meter – Gongyi, The product will supply to all over the world, such as: Puerto Rico , Kuwait , Ghana , We'll initiate the second phase of our development strategy. Our company regards "reasonable prices, efficient production time and good after-sales service" as our tenet. If you are interested in any of our products and solutions or would like to discuss a custom order, make sure you feel free to contact us. We've been looking forward to forming successful business relationships with new clients around the world in the near future.
  • The company account manager has a wealth of industry knowledge and experience, he could provide appropriate program according our needs and speak English fluently.
    5 Stars By Kay from Italy - 2017.11.11 11:41
    The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!
    5 Stars By Jeff Wolfe from Latvia - 2018.02.12 14:52

    Related Products