Reliable Supplier W1209 Digital Thermostat Temperature Controller Termostato Control Switch Sensor Module 12v

Short Description:

Our objective is to present premium quality products at aggressive prices, and top-notch services to buyers around the world. We have been ISO9001, CE, and GS certified and strictly adhere to their excellent specifications for Reliable Supplier W1209 Digital Thermostat Temperature Controller Term...


Product Detail

Product Tags

Our objective is to present premium quality products at aggressive prices, and top-notch services to buyers around the world. We have been ISO9001, CE, and GS certified and strictly adhere to their excellent specifications for Reliable Supplier W1209 Digital Thermostat Temperature Controller Termostato Control Switch Sensor Module 12v, We are able to give you quite possibly the most competitive rates and good quality, because we’re much additional Skilled! So make sure you will not wait to contact us.
Our objective is to present premium quality products at aggressive prices, and top-notch services to buyers around the world. We have been ISO9001, CE, and GS certified and strictly adhere to their excellent specifications for Temperature Controller W1209 Thermostat W1209, Termostato W1209 Termostato Digital Temperature Control, W1209 Digital Thermostat W1209 Dc 12v W1209 Temperature Controller, We always stick to the tenet of “sincerity, high quality, high efficiency, innovation”. With years of efforts, we’ve got established friendly and stable business relationships with worldwide customers. We welcome any of your inquiries and concerns for our solutions, and we’re sure that we are going to offer just what you want, as we always believe that your satisfaction is our success.

XMT*-308 Series intellgence digital temperature control instrument

Instruction Manual

Summarize

XMT*-308 series intelligent temperature controller, is single row 4-LED display. The controller can input kinds of signals which are used interchangeably,  three-button operation, adopts ON/OFF control and PID control. It can select Fahrenheit and degree centigrade temperature display. It allows an easy parameter setting and convenient inputting, is used widely temperature automatic control systems of machinery、chemical、ceramics、light industrial、metallurgy、petrifaction and heat treatment and so on.

Ⅱ、Main Technical Indexs

1、Measurement deviation:±0.5%F·S±1B,Cold end compensating deviation≤±2℃

2、Input(can be selected):CU50、PT100、K、E、J、T、S

3、Relay output contact capacity:AC220V  5A(resistance load)period 2~120s can be adjusted.

4、Driving solid relay signal output:driving electric current>15m A  voltage>9V,period is 2S

5、Power:AC85V~242V,50~60HZ

6、Work environment:temperature 0~50.0℃, relative humidity≤85%RH, without corrode and strong electric radiation.

Ⅲ、Instrument panel and connection scheme(consult) 

1

Technical Indexes

 1 2 3

  

     

Flow chart 

2

Operation

1、 Electrify after take into the power, sensor and control circuit according to the connection scheme, and then the instrument start testing itself for 1 second.

2、 Set the setting value

Press ▲or ▼key 3 second enter to the setting value states. press▲or ▼key to modify,for long time to press the key can accelerate. After modification, press SET to save and exit. if you don’t do this operation, it can be done itself.

3、 Interior Technical parameter setting(Technical parameter refer to the sheet)

(1) The first menu   

Press SET key 3 second enter into the first menu, the window display parameter code then display parameter value. Press▲or ▼key to modofy,for long time to press the key can accelerate. .After modification, press SET key to save and enter into next Indexs setting. if you don’t do this operation, it can be done itself.

(2)The second menu Press  SET & ▲ key to enter into the second menu, and the setting method is the same as the first menu.

 4. Set by itself

First ,set the setting value, and enter the menu, set  to , and the AT light turn on,the meter enter the condition setting itself,this time the meter adopt on/off control mode, after three times surge(first time, measure value and  display by turns; second time, measure value and  display by turns; second time , measure value and  display by turns),the meter confirm new、、 and save it, the meter reset and(display、 by turns) enter control condition.

Ⅶ、Model Sense

XMT□— 3    □ 8     □

 1   2    3      4     5

1:External size and Installation hole(mm)

Empty: 160×80×90 152×76  A: 96×96×90      92×92

D: 72×72×90 68×68  E: 48×96×90      44×92

F: 96×48×90  92×44   G: 48×48×100     44×44

S: 80×160×90 76×152  B: 60×120×90     56×116

 K: 48×24×80  44×21  FC: 77×35×76      71×29

L:35mm DIN guide rail installation  C:80×120×35    wall set installation

2.Operation display method:‘3’ 3-key soft push-switch setting, single row digital display, have PID adjustment or  ON/OFF control

3: An additional alarm ‘0’indicates no alarm;‘1’upper limit touch alarm;‘2’ lower limit touch alarm

4:Input signal classification: ‘8’input signal can interchange free

5:Suffix empty:relay output  G:solid state relay output            

A:mono-phase over zero trigger output   

Fault Analysis and Clearance

XMT*-308 adopts advanced production process, and has the strict test before leaving factory, it improve the reliability of the meter .The usual fault is caused by the wrong operation or parameter setting .If you find the fault couldn’t be cope with, please record it,and contact with the agent or us. Sheet 8-1 is the usual fault of XMT*-308 in the daily application:

Sheet 8-1 Common fault handling