Short Description:

EU-08RTPDigital temperature display/control instrument Ⅰ、Main Technical Indexes1. Measurement deviation:Class±0.5%F·S±1B,additional cold end compensationdeviation ±1℃2. Input Type:CU50(-50~150.0)、PT100(-199.9~600.0)、K(-30~1300)、E(-30~700)、J(-30~900)、T(199~400)、S(-...


Product Detail

Product Tags

Related Video

Feedback (2)

We've got a specialist, effectiveness staff to supply high quality service for our shopper. We always follow the tenet of customer-oriented, details-focused for Temperature Sensor Rtd Pt100 , Digital Temperature Indicator , Voltage Regulator , Warmly welcome to cooperate and develop with us! we are going to continue to provide product or service with high quality and competitive rate.
OEM China Indoor And Outdoor Temperature Sensor - EU-08 Universal Input Type Intelligent Temperature Controller – Gongyi Detail:

EU-08RTP

Digital temperature display/control instrument 

Ⅰ、Main Technical Indexes

1. Measurement deviation:Class±0.5%F·S±1B,additional cold end compensation

deviation ±1℃

2. Input Type:CU50(-50~150.0)、PT100(-199.9~600.0)、K(-30~1300)、

E(-30~700)、J(-30~900)、T(199~400)、S(-30~1600)、

R(-30~1700)、0~10V (-1999~9999) 、4~20mA (-1999~9999)、

3. Relay output contact capacity:AC220V , 5A(resistance load)

4. Linearity output:4~20mA(Client can adjust by himself)

5. Power output: 24VDC

6. 0.8"LED tube and four digit display

7. Size and Installation hole(mm):96×48×110   92×44

8. Working power:AC 85V~242V,50/60HZ

9. Working condition:0~50℃,relative humidity≤85%,without corrode and strong electric radiation.

Ⅱ、Instrument panel and connection scheme

1

Notice: linearity voltage0~10V can be input directly by 1、4 terminaland the input of linearity current  4~20 mA  can connect 4、5 terminal use lead then input signal from 1、4 terminal.

Ⅲ、Interior parameter

1

Notice:When thermocouple and thermal resistance input,the decimal point set up the range of

0~1;when current and voltage input ,the decimal point set up the range of 0~3。

Meter flow chart:

 3

Ⅳ、Meter Operation 

1、 Electrify after take into the power,sensor and control circuit according to the connection scheme,and then the instrument start testing itself for 1 second.

2、Interior parameter setting(Technical Indexes refer to the sheet3-1)

(1) The first menu

Press SET key 3 second enter into the first menu,the window display parameter code then display parameter value.Press▲or ▼key to modofy,for long time to press the key can accelerate. After modification,press SET key to save and enter into next Indexs setting. If within 10 seconds do not press every key then it will automatically to preserve the data and withdraw the setting.  (2) The second menu

Press SET and▲key 3 second enter into the second menu,and the setting method is the same as the first menu.

3、linearity output

Parameter OUTH、OUTL output upper limit and lower limit for linearity current;When output is 4~20mA,OUTL=40,OUTH=200,the client can adjust by himself through connecting ammeter.

4. Some useful samples for calibration :

(1). For input of 4-20mADC ( or 0-10V), Such as

If you want to display 4mA=0 and 20mA=1000, normally set DIL=0 and DIH=1000.In case it displays 4mA=0 and 20mA=993, Please reset DIL=0 and DIH=1007 for calibration. After calibration , the meter will display 4mA=0 and 20mA=1000 as you expect.

(2).SC setting: It is usefull calibration for different between display value and measuring value.

For example , If the measuring value is 3 more or less than display valve, set SC=-3 or 3 for calibration.

Ⅴ、Fault Analysis and Clearance

EU-08RTP adopts advanced production process, and has the strict test before leaving factory, it improve the reliability of the meter .The usual fault is caused by the wrong operation or parameter setting .If you find the fault couldn’t be cope with, please record it,and contact with the agent or us. Sheet 5-1 is the usual fault of EU-08RTP in the daily application:

Sheet 5-1 Common fault handling

zh

Attached 1:Statement of meter’s parameter attention letter and English letter

2

Remark:Our company will improve product technology、design and specification,it is confirm to the object.

 


Product detail pictures:

OEM China Indoor And Outdoor Temperature Sensor -
 EU-08  Universal Input Type Intelligent Temperature Controller – Gongyi detail pictures

OEM China Indoor And Outdoor Temperature Sensor -
 EU-08  Universal Input Type Intelligent Temperature Controller – Gongyi detail pictures


Related Product Guide:
Cooperation

We can always satisfy our respected customers with our good quality, good price and good service due to we are more professional and more hard-working and do it in cost-effective way for OEM China Indoor And Outdoor Temperature Sensor - EU-08 Universal Input Type Intelligent Temperature Controller – Gongyi, The product will supply to all over the world, such as: Atlanta , Morocco , Johor , Many goods fully conform to the most rigorous of international guidelines and with our first-rate delivery service you will have them delivered at any time and in any place. And because Kayo deals in the entire spectrum of protective equipment, our customers don't have to waste time shopping around.
  • Production management mechanism is completed, quality is guaranteed, high credibility and service let the cooperation is easy, perfect!
    5 Stars By Madge from Nepal - 2017.01.28 18:53
    We feel easy to cooperate with this company, the supplier is very responsible, thanks.There will be more in-depth cooperation.
    5 Stars By Nancy from Qatar - 2017.09.26 12:12

    Related Products