Newly Arrival Humidity Controller For Incubator - XMT-7000 Series Single Input Type Intelligent Temperature Controller – Gongyi

Short Description:

XMT*7000 Series intelligence digital temperature control instrument Instruction ManualⅠ、Product characteristic:The core of the product adopts the up-to-date microprocessor chip.Red and green double-bank nixie tube display the measured value and setting value.Easy operation in the four/three...


Product Detail

Product Tags

Related Video

Feedback (2)

Persisting in "High quality, Prompt Delivery, Competitive Price", we have established long-term cooperation with clients from both overseas and domestically and get new and old clients' high comments for Rail Mounting Temperature Controller , Digital Thermometer With Sensor , Automatic Temperature Humidity Controller , We welcome shoppers, business enterprise associations and close friends from all sections with the globe to contact us and seek cooperation for mutual added benefits.
Newly Arrival Humidity Controller For Incubator - XMT-7000 Series Single Input Type Intelligent Temperature Controller – Gongyi Detail:

XMT*7000 Series intelligence digital temperature control instrument

Instruction Manual

Ⅰ、Product characteristic:

The core of the product adopts the up-to-date microprocessor chip.

Red and green double-bank nixie tube display the measured value and setting value.

Easy operation in the four/three keys, & fast setting in the parameter.

Control in high precision’s PID intelligent and two or three bit location check program.

Upper-bank display the measured value, & bottom-bank display the setting value under normal working conditions.

Ⅱ、Primary technical standard:

Input: Thermocouple: K、E、J、S Thermal resistance: PT100 、 CU50

Range: K(0~400℃、0~1300℃)、E(0~400℃、0~800℃)、J(0~1000℃)、 S(0~1600℃)、PT100(-100.0~200.0℃、0~600℃)、CU50(-50.0~150.0℃)Measure error: ±0.5%F.S±1byte

Silicon control trigger signal(over zero): Range≥3V, Width≥40us

The output contact potential of the relay: impedance load AC220V  5A

Input power: AC85~242V   50/60Hz

Environment:  Temperature: 0 to 50℃,  Humidity: ≤85%RH

1

(1)PV displayIndicates  the process variable (PV) with a red LED.

(2)SV displayIndicates  the setting value (SV) with a green LED.

(3)AT indicator When auto tuning function is ON, a green LED lights.

(4)ALM1 indicator When ALM1 output is ON, a red LED lights.

(5)ALM2 indicator When ALM2 output is ON, a red LED lights.

(6)OUT indicator When OUT is ON, a green LED lights.

(7)Mode key (SET) Switches the setting mode and registers the setting value and selected value.(Setting value and selected value are registered by pressing the mode key.)

(8)Data shift key (<)

(9)Decrease key (∨)Decreases numeric value of the setting value

(10)rease key (∧)Increases numeric value of the setting value.

Note: XMTG-7000 only has three keys, has not Data shift key and ALM2 indicator.

Ⅳ、Setup flow chart

Size: XMT:160×80×125mm  hole:152×76;  XMTA:96×96×85mm  hole: 92×92;

XMTE:48×96×85mm   hole: 44×92;  XMTF:96×48×85mm   hole: 92×44;

XMTD:72×72×85mm   hole: 68×68;  XMTG:48×48×110mm   hole: 44×44;  

Ⅲ、Name and functions of the sections(consult)

1

Ⅴ、Display Status(consult) 

2

Note:  1. LC is key lock. It can rework all parameter when LC is 0. It can only rework SP value when LC is 1.

2. The no all meter have up wards parameters, only answer for correspond to function

meter have corresponding parameters.

l Connect the power, the sensor and the external control circuit to the instrument refer to the connection figure. After these, turn on the power and then the instrument will at first begin to auto-test according to the program A, Band C.

A: All LEDS and all indicating lamps will be lighted to test the lighting-system whether good or not. If unlighted LED or indicating lamp were found, please stop using and transmit it to for repairation. (This procedure lasts for 0.5s)

B: The window PV (upper window) display “CJ”, the window SV is not display.

C: The window PV display model.

After the three procedures, the instrument will step into the normal measure-control state. The upper window PV display the value that the instrument is measuring and the lower window SV display the value set.

l If want to modify the value in the window SV, press the SET key 3 second when the instrument is in its normal display state, then the window PV will display “SP” and the window SV will point wink. At this moment press the key ∧ to increase the value or the key ∨ to decrease (Press the key ∧ or ∨ for a longer time to accelerate the speed of value setting). Press < key shift (like cursor). Press the key SET to certain the modified value. If no any other operation after modification, the instrument will automatically return to the normal display state and accept the modified value at the same time.

l If want to modify the value other than “SP”, press the key (SET+∧) 3 second when the instrument is in its normal display state to set the internal parameter. Please set the value in terms of the actual application. But please pay more attention to the three items “P、I、d”, these must be set by experienced engineer.

l Auto-man: the first set value is OK, after at being “1”, the “AT” indicating to it will light. The instrument begins working as the ordinary one with two control points and three states. After 3 cycles, it will certain the best PID value to the set point and store it forever unless the user’s modification or opening the “AT” function.

l The signal “HH” or “LL” in the window PV means that the sensor is out of connection or the measured value is overflow.

Ⅵ、Connection figure(consult)   

3

Note:The connection wire drawing only for reference,it should be subject to the attached drawing.

Ⅶ、Fault Analysis and Clearance

XMT*-7000 adopts advanced production process, and has the strict test before leaving factory, it improve the reliability of the meter .The usual fault is caused by the wrong operation or parameter setting .If you find the fault couldn’t be cope with, please record it,and contact with the agent or us. Sheet 7-1 is the usual fault of XMT*-7000 in the daily application:

Sheet 7-1 Common fault handling
22

Attached 1Statement of meter’s parameter attention letter and English letter

2

★ RemarkOur company will improve product technologydesign and specificationit is confirm to the object.

Product detail pictures:

Newly Arrival Humidity Controller For Incubator -
 XMT-7000 Series Single Input Type Intelligent Temperature Controller  – Gongyi detail pictures

Newly Arrival Humidity Controller For Incubator -
 XMT-7000 Series Single Input Type Intelligent Temperature Controller  – Gongyi detail pictures

Newly Arrival Humidity Controller For Incubator -
 XMT-7000 Series Single Input Type Intelligent Temperature Controller  – Gongyi detail pictures

Newly Arrival Humidity Controller For Incubator -
 XMT-7000 Series Single Input Type Intelligent Temperature Controller  – Gongyi detail pictures

Newly Arrival Humidity Controller For Incubator -
 XMT-7000 Series Single Input Type Intelligent Temperature Controller  – Gongyi detail pictures

Newly Arrival Humidity Controller For Incubator -
 XMT-7000 Series Single Input Type Intelligent Temperature Controller  – Gongyi detail pictures

Newly Arrival Humidity Controller For Incubator -
 XMT-7000 Series Single Input Type Intelligent Temperature Controller  – Gongyi detail pictures

Newly Arrival Humidity Controller For Incubator -
 XMT-7000 Series Single Input Type Intelligent Temperature Controller  – Gongyi detail pictures


Related Product Guide:
Cooperation

Bear "Customer first, High quality first" in mind, we perform closely with our consumers and provide them with efficient and experienced services for Newly Arrival Humidity Controller For Incubator - XMT-7000 Series Single Input Type Intelligent Temperature Controller – Gongyi, The product will supply to all over the world, such as: Washington , Colombia , United States , We are adhering to the philosophy of "attracting customers with the best products and excellent service". We welcome customers, business associations and friends from all parts of the world to contact us and seek cooperation for mutual benefits.
  • It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
    5 Stars By Lilith from Dubai - 2017.03.28 12:22
    The enterprise has a strong capital and competitive power, product is sufficient, reliable, so we have no worries on cooperating with them.
    5 Stars By Delia from Zambia - 2018.09.29 17:23

    Related Products