Low MOQ for Scr Voltage Controller - XMT-JK408 Series Multi Way Intelligent Temperature Controller – Gongyi

Short Description:

XMT*JK four-way temperature controllerInstruction manualⅠ、SummaryXMT*JK four-way temperature controller can connect four sensors synchronously and conveniently, diminish the instrument’s volume. It has a separate auto-tune mode and PID parameter function with more precision and more reliabili...


Product Detail

Product Tags

Related Video

Feedback (2)

We persist with the principle of "quality 1st, assistance initially, continual improvement and innovation to meet the customers" for your management and "zero defect, zero complaints" as the standard objective. To great our service, we present the products and solutions while using the very good top quality at the reasonable cost for Temperature Humidity Data Logger Wireless , Pt100 Temperature Sensor , Thermocouple Temperature Controller , To provide customers with excellent equipment and services, and constantly develop new machine is our company's business objectives. We look forward to your cooperation.
Low MOQ for Scr Voltage Controller - XMT-JK408 Series Multi Way Intelligent Temperature Controller – Gongyi Detail:

XMT*JK four-way temperature controller

Instruction manual

Ⅰ、Summary

XMT*JK four-way temperature controller can connect four sensors synchronously and conveniently, diminish the instrument’s volume. It has a separate auto-tune mode and PID parameter function with more precision and more reliability in whole machine control.  

Ⅱ、Primary technical standard:

1、Input signal: CU50(-50.0~150.0℃)、Pt100(-19.9~600.0℃)、K(0~1300℃)、

E(0~700.0℃)、J(0~900.0℃)

2、Accuracy: ±0.5%F.S±byte

3、Output  method:  relay  AC220V  3A(resistance load)

4、control mode: difference control-on/off and PID control

5、Input power: AC110~242V   50/60Hz

6、Environment Temperature: 0 to 50℃,  Humidity: ≤85%RH

7、Face Size: 160×80×110 mm      Hole Size : 152×76 mm 96×96×110 mm       Hole Size : 92×92 mm  72×72×110 mm       Hole Size :68×68 mm

Ⅲ、Panel board instruction

1

Ⅳ、connection scheme

2

connection indicator :

PS:1、MiNi printer connection

1

2、RS485 communication:connect corresponding ‘VA+,VB-’.

3、RS232 communication:connect corresponding ‘R’、‘T’、‘GND’.

4、only one function can be used between printer and communication functions at one time.

Ⅴ、Code setting mode

1 2 3


Ⅵ、Technical indexes

1.Accurately connect uires according as connect indicator,power on.

2.Press ‘SET key’ for 3 seconds,enter into first menu.then ‘parameter ’and paraneter value tims will be shown respectively about ‘CH1 window’ and ‘CH2 window’,you can adjust these parameters by poressing ‘▲’、‘▼’、‘◄’、and save the setting by prwss ‘SET key ’,every parameter should be saved after setting ,then enter next parameter set.

3.You can press ‘CH1’、‘CH2’、‘CH3’、‘CH4’ for 3 seconds to enter into corrseponding channel menu .After finished one parameter set,press ‘SET’ to save it,then enter into next parameter set .

Ⅶ、Setting itself

The meter use in the first time or the surroundings have changer, finding it control not good, in this time you need use the setting itself. For example:The first set the AT=1,A-M light flickered, the meter enter into setting itself, press the SET key enter into parameter setting. Set the Hy is 0.5~1℃, if the output is relay set the t=2S, the meter have three times vibrate, automatic preserved P, I, D parameter and the A-M light off, the setting itself finish.

Fault Analysis and Clearance

XMT*JK408 adopt advanced production process, and have the strict test before leaving factory, it improve the reliability of the meter .The usual fault caused by the wrong operation or parameter setting .If you find the fault couldn’t be cope with, please record it, and contact with the agent or us. Sheet 8-1 is the usual fault of XMT*JK408 in the daily application:

Sheet 8-1 Common fault disposal

zh

★Remark:Our company will improve product technology, design and specification, it is confirm to the object.

Attached 1:Statement of meter’s parameter attention letter and English letter

2

Product detail pictures:

Low MOQ for Scr Voltage Controller -
 XMT-JK408 Series Multi Way Intelligent Temperature Controller – Gongyi detail pictures

Low MOQ for Scr Voltage Controller -
 XMT-JK408 Series Multi Way Intelligent Temperature Controller – Gongyi detail pictures

Low MOQ for Scr Voltage Controller -
 XMT-JK408 Series Multi Way Intelligent Temperature Controller – Gongyi detail pictures

Low MOQ for Scr Voltage Controller -
 XMT-JK408 Series Multi Way Intelligent Temperature Controller – Gongyi detail pictures

Low MOQ for Scr Voltage Controller -
 XMT-JK408 Series Multi Way Intelligent Temperature Controller – Gongyi detail pictures

Low MOQ for Scr Voltage Controller -
 XMT-JK408 Series Multi Way Intelligent Temperature Controller – Gongyi detail pictures


Related Product Guide:
Cooperation

We believe in: Innovation is our soul and spirit. Top quality is our life. Purchaser need is our God for Low MOQ for Scr Voltage Controller - XMT-JK408 Series Multi Way Intelligent Temperature Controller – Gongyi, The product will supply to all over the world, such as: Cologne , Colombia , Bangkok , We set a strict quality control system. We have return and exchange policy, and you can exchange within 7 days after receive the wigs if it is in new station and we service repairing free for our products. Please feel free to contact us for further information and we will offer you competitive price list then.
  • The supplier abide the theory of "quality the basic, trust the first and management the advanced" so that they can ensure a reliable product quality and stable customers.
    5 Stars By Roland Jacka from Vancouver - 2018.06.28 19:27
    This is a very professional and honest Chinese supplier, from now on we fell in love with the Chinese manufacturing.
    5 Stars By Maggie from Auckland - 2017.02.18 15:54

    Related Products