Factory wholesale Temperature Control Switch - D Series Digital Voltmeter – Gongyi

Short Description:

Ⅰ、Survey:D series intellective electric meter(Digital Ammeter、Digital Voltmeter、Frequency Meter、Tachometer and so on)is a type of multifunctional composite type meter, it apply to electric power and electric network, field monitoring and display of automatic control systems and remote con...


Product Detail

Product Tags

Related Video

Feedback (2)

Innovation, excellent and reliability are the core values of our company. These principles today much more than ever form the basis of our success as an internationally active mid-size business for Humidity Controller , Analog Output , Digital Thermometers , Therefore, we can meet different inquiries from different clients. Please find our website to check more information from our products.
Factory wholesale Temperature Control Switch - D Series Digital Voltmeter – Gongyi Detail:

Ⅰ、Survey:

D series intellective electric meter(Digital Ammeter、Digital Voltmeter、Frequency Meter、Tachometer and so on)is a type of multifunctional composite type meter, it apply to electric power and electric network, field monitoring and display of automatic control systems and remote control and measurement of automatic dispatch telemechanical device,its function is to output  standard current or voltage transfer signal using CPU operation electric network’s parameter, such as current、voltage、3 phase power、frequency and so on,and then A/D’s conversion. Also this meter has RS232 or RS485 communication interface be joined with long range data terminal TRU.

Ⅱ、Main technical specification

1、Accuracy Class: 0.5%F·S±1B

2、Display Digit:4

3、Reference Input:AC /AV:0~5A/0~500V   volts D.C.:0~199.9V   0~1000V

4、Power consumption:≤3W

5、Working power:AC85~242V,50/60HZ

6、Working circumstance:0~50℃,relative humidity≤85%,without corrode and electric radiation

Ⅲ、Panel board and connection

1、Panel board  

1

The panel board function of each model can follow the above drawing .

2、connection

2

Ⅳ、Operation

1、Interior parameter(only Current、Voltage model meter have this parameter)

Series

Attention

Name

Setting range

Manual

Remarks

0 LocK

Electronic lock

0255

Lock=18all the parameter can be Revised.  

18

1

 

dP

Display precision

03

dp0the decimal doesn’t display

dp1the decimal in tens

dp2the decimal in hundreds

dp3the decimal in thousands

0

2

dIH

Set upper limit Setting range determined by dpis in turn 9.999

99.99999.99999

2、Operational flowchart

3

3、connect according to the connection, the instrument will test by itself for 1S.

4、Interior parameter setting(parameter definition refer to parameter sheet)

Press SET key for 3S to enter the Interior parameter setting state,it display parameter code first,and then display parameter value after 2s,press▲、▼ to modify parameter value,and press SET to save and enter the next parameter setting ,exit till the setting finished. If not press any key ,it will save and exit automatically. 

5、★current、voltage mode:if the meter display has warp,you can press ‘SET’&▲&▼key at one time to clear.(please be cautious to use this function).

Ⅴ、Meaning of the model code

D □  □-□□   □- □

①   ②    ③    ④     ⑤     ⑥     

①:Series number L:Current model  Y:Voltage model   F-frequency   R-revolving speed

②:External dimension and Installation hole(mm):

T:160×80×85  156×76       A:96×96×90    92×92      D:72×72×90    68×68     

E:48×96×75    44×92       F:96×48×75    92×44       G:48×48×105   44×44

③:3-key soft push-switch setting, single row digital display,

④: Control output:  0: No alarm   1: A alarm   3: Two alarms  4: PID bit control  

5: PID solid-state control  6: PID SCR phase shifter control  7: PID SCR zero-crossing control
8: SCR three-phase zero-crossing control  9:4 ~ 20mA control output
⑤: The input nominal value:
No: AC current 5A input, the AC current for 0-9999 arbitrary setting, apply to all transformer       ammeter;   AC voltage for 0-500.0VAC;   

10: 0 ~ 10A  400: 0 ~ 400V  0.2: 0 ~ 200mA
⑥: Suffix: K-  RS485 communication function

Ⅵ、Fault Analysis and Clearance

Sheet 6-1 Common fault handling

fault symptom analysis of causes Disposal  measurement
The power on is unusual 1poor contact of power cord  

2power switch without lose

Check the power
Signal display do not correlate with the facts.(displayHHor0’) 1、Input nominal value overtop or under the meter’s display range Check the input value

Product detail pictures:

Factory wholesale Temperature Control Switch -
 D Series  Digital Voltmeter – Gongyi detail pictures

Factory wholesale Temperature Control Switch -
 D Series  Digital Voltmeter – Gongyi detail pictures

Factory wholesale Temperature Control Switch -
 D Series  Digital Voltmeter – Gongyi detail pictures

Factory wholesale Temperature Control Switch -
 D Series  Digital Voltmeter – Gongyi detail pictures


Related Product Guide:
Cooperation

With a complete scientific quality management system, good quality and good faith, we win good reputation and occupied this field for Factory wholesale Temperature Control Switch - D Series Digital Voltmeter – Gongyi, The product will supply to all over the world, such as: Tanzania , Kuala Lumpur , Pakistan , Adhering to the principle of "Enterprising and Truth-Seeking, Preciseness and Unity", with technology as the core, our company continues to innovate, dedicated to providing you with the highest cost-effective solutions and meticulous after-sales service. We firmly believe that: we're outstanding as we have been specialized.
  • A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 Stars By Carlos from Dominica - 2018.12.10 19:03
    We are really happy to find such a manufacturer that ensuring product quality at the same time the price is very cheap.
    5 Stars By Marguerite from New York - 2017.08.16 13:39

    Related Products