Excellent quality Electric Energy Meter Enclosure - Safety Fence – Gongyi

Short Description:

Ⅰ.General introduction First of all thank you for using our meter, This manual contains instructions for the installation of meters, operations, parameter setting in the PC. Safety fence is a new type of meter that our Company recently developed, using photoelectric isolation technology, SMT ma...


Product Detail

Product Tags

Related Video

Feedback (2)

We've been committed to offering easy,time-saving and money-saving one-stop purchasing service of consumer for Xmt Pid Temperature Controller , 3 Phase Power Stabilizer , Current Meter , We have a big inventory to fulfill our customer's demands and needs.
Excellent quality Electric Energy Meter Enclosure - Safety Fence – Gongyi Detail:

.General introduction

First of all thank you for using our meter, This manual contains instructions for the installation of meters, operations, parameter setting in the PC. 

Safety fence is a new type of meter that our Company recently developed, using photoelectric isolation technology, SMT manufacturing process and international standards DIN Rail installation, and have a wide voltage, small size, long life, easy-to-install, and strong anti-interference, and other advantages. Instrumentation is for a group of signal input, two groups simultaneous signal output, communication using ModBus agreement, through RS-485 interface with the PC or PLC-controlled part on-line to concentrate on monitoring and control meters, in connection with the PC Meter can amend the parameters through PC.

. Technical Index

1、Input type: CU50、PT100、K、E、J、T、S、R、WR25、N、F2、0-5V、1-5V

2、Output precision : ±0.5%F.S 

3、Output signal: two group 4~20mA(adjustable through parameter OUTH、OUTL)

4、Overall dimension(mm):106×76×25

5、Power supply:AC/DC 24~36V   

6、Working circumstance:temperature 0~50℃,humidity﹤85%RH without.

corrode and strong electromagnetism disturb.

. Size appearance and meter connection schemeconsult

0

. Code setting mode

Series    code   Name             Remark Setting range Ex-Factory
1  Pb Sensor erroramendment The sensor have deviation can use itemto revisal 0±20.0   0.0
2 FILT Filt modulus The first order lag filter coefficient, the value is greater, the performance anti-jamming moment is stronger, but the response time lag. The pressure and flow control of its value should be smaller, temperature and level control should be relatively large 050 20
3 OUTH Allow exportsmax value Restrain maximum value of adjust output. outL2200 2000
4 OUTL Allow exports  min value Restrain minimum value of adjust output 0outH 400
5 LocK Code lock 0-all the parameter can be revised1-only the SP can be revised 050 0
 

6

 

Sn

 

Input type

‘0’Cu50 –50.0150.0℃‘1’Pt100 –199.9200.0℃‘2’Pt100 –199.9600.0℃;  ‘3’K  -30.01300℃‘4’E  -30.0700.0℃ ;   ‘5’ J  -30.0900.0℃

‘6’T  -199.9400.0℃;    ‘7’ S  -301600℃

‘8’  R  -30.01700.0℃;    ‘9’  WR25 -30.02300.0℃;     

‘10’  N -30.01200.0℃;      ‘11’  Idiosyncratic type

‘12’ 05V(010mA);       ‘13’ 15V(420mA)  

 

013

 

random

7  P-SH Display the high limit P-SH decide the display range, the value and unit are  decided  by  factory and client freely. P-SL9999 random
8 P-SL Display the low limit P-SL decide the display range, the value and unit are decided  by  factory and client freely. -1999P-SH random
9 Addr Communication addres The meter’s number in the control system 063 0
10 BAud Communication baud rate ‘0’1200‘1’2400‘2’4800‘3’9600 03 9600

When the meter connect the PC hrough the RS-485, it can amend meter parameters through the PC, parameters order please refer to Table 4-1. The default address for its communications “0″, the baud rate for “9600″. To connect multiple meters, the PC software address amend for “0″, baud rate changed to “9600″, at this time connecting on a meter, the menu address parameters will be changed to other numerical parameters (not larger than 63), after editing and then another meter to amend the address. Each meter is the only address, can not be repeated. And so on until the end of amending the connecting instrument..Meter communications and parameters amending

Note: When the meter amended the address, the address numerical value labeled best on the meter avoiding confusion. PC software use refers to the help function in PC software.  

4~20mA or 0~10mA linearity current input can achieve by changing 250Ω or 500Ωresistance to 1~5V or 0~5V voltage signal,and then input from A2、28 terminal.

. Fault Analysis and Clearance

Safety fence adopt advanced production process, and have the strict test before leaving factory, it improve the reliability of the meter .The usual fault caused by the wrong operation or parameter setting .If you find the fault couldn’t be cope with, please record it,and contact with the agent or us. Sheet 6-1 is the usual fault of Safety fence in the daily application:

Sheet 6-1 Common fault handling

fault symptom analysis of causes Disposal  measurement
Abnormal power 1Poor contact of power cord

2Power switch without lose

Check the power
PC display do not correlate with the facts.display‘FF’ 1Sensor model mismatch

2Wrong signal connection

1Check sensor model and meter interior input parameter 2check signal wire

3Check communication wire

Abnormal output 1Wrong connecting output wire 1Check output connection

2Check parameter OUTHOUTL


Product detail pictures:

Excellent quality Electric Energy Meter Enclosure -
 Safety Fence – Gongyi detail pictures

Excellent quality Electric Energy Meter Enclosure -
 Safety Fence – Gongyi detail pictures


Related Product Guide:
Cooperation

We have been proud from the higher consumer gratification and wide acceptance due to our persistent pursuit of high quality both on product or service and service for Excellent quality Electric Energy Meter Enclosure - Safety Fence – Gongyi, The product will supply to all over the world, such as: Malta , Liverpool , Australia , "Good quality, Good service " is always our tenet and credo. We take every effort to control the quality, package, labels etc and our QC will check every detail during producing and before shipment. We are willing to establish long business relationship with those who seek the high quality products and good service. We have set up a wide sales network across European countries, North of America, South of America, Middle East, Africa, East Asia countries.Please contact us now, you will find our professional experience and high quality grades will contribute to your business.
  • The supplier abide the theory of "quality the basic, trust the first and management the advanced" so that they can ensure a reliable product quality and stable customers.
    5 Stars By Barbara from Poland - 2018.10.09 19:07
    The sales manager is very patient, we communicated about three days before we decided to cooperate, finally, we are very satisfied with this cooperation!
    5 Stars By Elizabeth from venezuela - 2017.07.07 13:00

    Related Products