Europe style for Time Delay Relay - Special Design for K Type Industrial Digital Thermocouple Contact Thermometer Dual-channel Temperature Meter Tester For K/j/t/e/r/s/n Thermocouple – Gongyi

Short Description:

In the past few years, our business absorbed and digested advanced technologies both equally at home and abroad. In the meantime, our company staffs a group of experts devoted to your advancement of Special Design for K Type Industrial Digital Thermocouple Contact Thermometer Dual-channel Tempera...


Product Detail

Product Tags

Related Video

Feedback (2)

We insist about the theory of growth of 'High excellent, Performance, Sincerity and Down-to-earth working approach' to offer you with great company of processing for Scr Ac Power Control , Pressure Level Temperature Pid Controller , Digital Temperature Sensor , All the time, we have been paying attention on all details to insure each product satisfied by our customers.
Europe style for Time Delay Relay - Special Design for K Type Industrial Digital Thermocouple Contact Thermometer Dual-channel Temperature Meter Tester For K/j/t/e/r/s/n Thermocouple – Gongyi Detail:

In the past few years, our business absorbed and digested advanced technologies both equally at home and abroad. In the meantime, our company staffs a group of experts devoted to your advancement of Special Design for K Type Industrial Digital Thermocouple Contact Thermometer Dual-channel Temperature Meter Tester For K/j/t/e/r/s/n Thermocouple, We’ve been not pleased while using the present achievements but we are trying finest to innovate to satisfy buyer’s much more personalized needs. No matter where you will be from, we have been here to wait for your sort ask for, and welcom to go to our manufacturing facility. Choose us, you can meet your trusted supplier.
In the past few years, our business absorbed and digested advanced technologies both equally at home and abroad. In the meantime, our company staffs a group of experts devoted to your advancement of K Type Industrial Digital Thermocouple, Temperature Meter, Thermocouple Thermometer, we’re now looking forward to even greater cooperation with overseas customers based on mutual benefits. We are going to work wholeheartedly to improve our products and services. We also promise to work jointly with business partners to elevate our cooperation to a higher level and share success together. Warmly welcome you to visit our factory sincerely.

XMT*9000 Series intelligence digital temperature control instrument

Instruction Manual

Ⅰ、Product characteristic:

The core of the product adopts the up-to-date microprocessor chip.

Red and green double-bank nixie tube display the measured value and setting value.

Easy operation in the four/three keys, & fast setting in the parameter.

Control in high precision’s PID intelligent and two or three bit location check program.

Upper-bank display the measured value, & bottom-bank display the setting value under normal working conditions.

Ⅱ、Primary technical standard:

Input: Thermocouple: K、E、J、S

Thermal resistance: PT100 、 CU50

Range: K(0~400℃、0~1300℃)、E(0~400℃、0~800℃)、J(0~1000℃)、

 S(0~1600℃)、PT100(-100.0~200.0℃、0~600℃)、CU50(-50.0~150.0℃)

Measure error: ±0.5%F.S±1byte

Silicon control trigger signal(over zero): Range≥3V, Width≥40us

The output contact potential of the relay: impedance load AC220V  5A

Input power: AC85~242V   50/60Hz

Environment:  Temperature: 0 to 50℃,  Humidity: ≤85%RH

Size: XMT:160×80×125mm  hole:152×76;  XMTA:96×96×85mm  hole: 92×92;

XMTE:48×96×85mm   hole: 44×92;  XMTF:96×48×85mm   hole: 92×44;

 XMTD:72×72×85mm   hole: 68×68;  XMTG:48×48×110mm   hole: 44×44;  

Ⅲ、Name and functions of the sections(consult)

1

(1)PV display Indicates the process variable (PV) with a red LED.

(2)SV display Indicates the setting value (SV) with a green LED.

(3)AT indicator When auto tuning function is ON, a green LED lights.

(4)ALM1 indicator When ALM1 output is ON, a red LED lights.

(5)ALM2 indicator When ALM2 output is ON, a red LED lights.

(6)OUT indicator When OUT is ON, a green LED lights.

(7)Mode key (SET) Switches the setting mode and registers the setting value and selected value.(Setting value and selected value are registered by pressing the mode key.)

(8)Data shift key (<)

(9)Decrease key (∨)Decreases numeric value of the setting value

(10)rease key (∧)Increases numeric value of the setting value.

Note: XMTG-7000 only has three keys, has not Data shift key and ALM2 indicator.

Ⅳ、Setup flow chart

Code Description Setting range  Instruction Remarks

SP

Setting control point

Whole range

or 1 defined unit _

AL1

Alarm 1

Whole range

or 1 defined unit

AL2

Alarm 2

Whole range

or 1 defined unit

SC

Measurement update

-20.0 to 20.0

Measuring value can be modified throughincreasing or decreasing this data.Note: It may be cause inaccurate racy of measuring value when you use this function. Please use the function carefully according to your situation.

0

P

Proportional band

0 to 9999

When the P,the proportion and differential function; if the P,the proportion and differential function. When P=0,the meter is ON/OFF control

100

I

Integration time

0 to 3000s

It’s mainly used to adjust the static difference. To increase it, the static difference will be reduced, but when it is too high, the static difference will drift instability.

500

d

Differential time

0 to 2000s

When the I,the calculus function; Ithe calculus function.When I=0, no calculus function, it is PD adjustment instrument

100

t

Control period

1 to 120s

When the d,the proportion and calculus function; if d,the proportion and calculus function,but the differential function.When dt, it has no differential function

20

Hy

Deadband

0.1to 50.0

ON/OFF control only

1.0

At

Auto-man

0 to 1

0- Close auto-man function1- Open auto-man function

0

Lock

Key lock

0 to 1

0- All the parameter can rework1- Only SP value can rework>1 All the parameter can not rework

0

Ⅴ、Display Status(consult) 

4

Note:  1. LC is key lock. It can rework all parameter when LC is 0. It can only rework SP value when LC is 1.

2. The no all meter have up wards parameters, only answer for correspond to function meter have corresponding parameters.

l Connect the power, the sensor and the external control circuit to the instrument refer to the connection figure. After these, turn on the power and then the instrument will at first begin to auto-test according to the program A, Band C.

A: All LEDS and all indicating lamps will be lighted to test the lighting-system whether good or not. If unlighted LED or indicating lamp were found, please stop using and transmit it to for repairation. (This procedure lasts for 0.5s)

B: The window PV (upper window) display “CJ”, the window SV is not display.

C: The window PV display model.

After the three procedures, the instrument will step into the normal measure-control state. The upper window PV display the value that the instrument is measuring and the lower window SV display the value set.

l If want to modify the value in the window SV, press the SET key 3 second when the instrument is in its normal display state, then the window PV will display “SP” and the window SV will point wink. At this moment press the key ∧ to increase the value or the key ∨ to decrease (Press the key ∧ or ∨ for a longer time to accelerate the speed of value setting). Press < key shift (like cursor). Press the key SET to certain the modified value. If no any other operation after modification, the instrument will automatically return to the normal display state and accept the modified value at the same time.

l If want to modify the value other than “SP”, press the key (SET+∧) 3 second when the instrument is in its normal display state to set the internal parameter. Please set the value in terms of the actual application. But please pay more attention to the three items “P、I、d”, these must be set by experienced engineer.

l Auto-man: the first set value is OK, after at being “1”, the “AT” indicating to it will light. The instrument begins working as the ordinary one with two control points and three states. After 3 cycles, it will certain the best PID value to the set point and store it forever unless the user’s modification or opening the “AT” function.

l The signal “HH” or “LL” in the window PV means that the sensor is out of connection or the measured value is overflow.

Ⅵ、Connection figure(consult) 

3

Note:The connection wire drawing only for reference,it should be subject to the attached drawing.

Ⅶ、Fault Analysis and Clearance

XMT*-9000 adopts advanced production process, and has the strict test before leaving factory, it improve the reliability of the meter .The usual fault is caused by the wrong operation or parameter setting .If you find the fault couldn’t be cope with, please record it,and contact with the agent or us. Sheet 7-1 is the usual fault of XMT*-7000 in the daily application:

Sheet 7-1 Common fault handling

fault symptom Analysis of causes Disposal  measurement
Abnormal power 1poor contact of power cord  2power switch without lose Check the power
Signal display do not correlate with the facts.display‘HH’or‘LL’ 1Sensor model mismatch2wrong signal connection 1check sensor model and meter interior input parameter 2check signal wire
Abnormal output control 1wrong connecting output wire 1check output connection

Attached 1:Statement of meter’s parameter attention letter and English letter

2

★ Remark:Our company will improve product technology、design and specification,it is confirm to the object.

Product detail pictures:

Europe style for Time Delay Relay -
 Special Design for K Type Industrial Digital Thermocouple Contact Thermometer Dual-channel Temperature Meter Tester For K/j/t/e/r/s/n Thermocouple – Gongyi detail pictures

Europe style for Time Delay Relay -
 Special Design for K Type Industrial Digital Thermocouple Contact Thermometer Dual-channel Temperature Meter Tester For K/j/t/e/r/s/n Thermocouple – Gongyi detail pictures

Europe style for Time Delay Relay -
 Special Design for K Type Industrial Digital Thermocouple Contact Thermometer Dual-channel Temperature Meter Tester For K/j/t/e/r/s/n Thermocouple – Gongyi detail pictures

Europe style for Time Delay Relay -
 Special Design for K Type Industrial Digital Thermocouple Contact Thermometer Dual-channel Temperature Meter Tester For K/j/t/e/r/s/n Thermocouple – Gongyi detail pictures

Europe style for Time Delay Relay -
 Special Design for K Type Industrial Digital Thermocouple Contact Thermometer Dual-channel Temperature Meter Tester For K/j/t/e/r/s/n Thermocouple – Gongyi detail pictures

Europe style for Time Delay Relay -
 Special Design for K Type Industrial Digital Thermocouple Contact Thermometer Dual-channel Temperature Meter Tester For K/j/t/e/r/s/n Thermocouple – Gongyi detail pictures


Related Product Guide:
Cooperation

We have now a specialist, efficiency staff to provide good quality company for our consumer. We normally follow the tenet of customer-oriented, details-focused for Europe style for Time Delay Relay - Special Design for K Type Industrial Digital Thermocouple Contact Thermometer Dual-channel Temperature Meter Tester For K/j/t/e/r/s/n Thermocouple – Gongyi, The product will supply to all over the world, such as: Puerto Rico , Greece , Estonia , we have complete material production line, assembling line , quality control system, and the most importantly, we have many patents technology and experienced technical&production team, professional sales service team. With all those advantages, we are going to create"the reputable international brand of nylon monofilaments", and spreading our products to every corner of the world. We are keep moving and try our best to serve our customers.
  • The after-sale warranty service is timely and thoughtful, encounter problems can be resolved very quickly, we feel reliable and secure.
    5 Stars By Lulu from Colombia - 2018.12.25 12:43
    High production efficiency and good product quality, fast delivery and completed after-sale protection, a right choice, a best choice.
    5 Stars By Margaret from Rio de Janeiro - 2018.06.12 16:22

    Related Products